ApplicationSpecifically designed for power stations, it can meet the temperature measurement needs of 300MW, 600MW, 1000MW and other generator sets and auxiliary equipment. Directly measure the temperature of liquid, steam and gas media, as well as solid surface temperatures within the range of -200
Application
Specifically designed for power stations, it can meet the temperature measurement needs of 300MW, 600MW, 1000MW and other generator sets and auxiliary equipment. Directly measure the temperature of liquid, steam and gas media, as well as solid surface temperatures within the range of -200°C to 800°C in production processes.
Working Principle
The electrodes of the thermocouple are composed of two different conductor materials. When there is a temperature difference between the measuring end and the reference end, a thermoelectric potential is generated, and the working instrument displays the temperature value corresponding to the thermoelectric potential.